How Can We Help?

Remote syslog

You are here:
< All Topics
Document Date and version2021.02.02
Tested with ONT HALNy HL-1GE, HL-1GE2, HL-4G, HL-4GMVSupported on Version: V2.0.9 or above
Tested with Ethernet Router HLE-4GMVSupported on Version: V2.0.18 or above
Tested with ONT HALNy HL-4GQV / HL-4GQVS / HL-4GQVS2 / HL-4GXV / HL-4GXV-FSupported on Version: V3.0.10 or above
Tested with Ethernet Router HLE-3GM / HLE-3GX-FSupported on Version: V3.0.12 or above
Tested with ONT HALNy HL-1B, HL-2BV, HL-4G2Supported on Version: V4.0.3 or above
Tested with ONT HALNy HL-4BX3V-F, HL-4GX3V-RSupported on Version: V5.0.8 or above
Tested with Ethernet Router HLE-4BX3V-FSupported on Version: V5.0.8 or above
Tested with ONT HALNy HLX-TGVSupported on Version: V6.0.3 or above
Revision1
Let us know how to improve below document on: support@halny.com

Why you need remote syslog:

When you want to troubleshoot something on ONT you may need to gather logs for a long time. Remote Syslog Server may help with that, because ONT has limited amount of memory and older logs may be overwritten

Firmware V2.0.X

Firmware V3.X.X, V4.0.X, V5.0.X, V6.0.X

<MANAGEMENT>
<SYSLOG>
<REMOTE_SYSLOG_ENABLE>YES</REMOTE_SYSLOG_ENABLE>
<REMOTE_HOST>192.168.33.200</REMOTE_HOST>
<REMOTE_PORT>5053</REMOTE_PORT>
</SYSLOG>
<MANAGEMENT>

Table of Contents