How Can We Help?
ONT HALNy Upgrade on HUAWEI MA5600T / MA5683T / MA5800-X15
Document Date and version | 2020.05.29 |
Tested on OLT Huawei MA5683T | Version: MA5600V800R017C10 |
Tested with ONT HALNy HL-1G, HL-GSFP | Supported on Version: 1.0.8 or above |
Tested with ONT HALNy HL-1GE, HL-1GE2, HL-1GC, HL-4G, HL-4GMV | Supported on Version: V2.0.10 or above |
Tested with ONT HALNy HL-2GRV, HL-4GQV, HL-4GQVS | Supported on Version: V3.0.3 or above |
Tested with ONT HALNy HL-4GMV2, HL-4GMV3, HL-4GMV4, HL-4GXV, HL-4GXV-F, HL-4GMVR | Supported on Version: V3.0.14p1 or above |
Tested with ONT HALNy HL-1B, HL-2BV, HL-4G2 | Supported on Version: V4.0.3 or above |
Tested with ONT HALNy HL-4BX3V-F, HL-4GX3VR | Supported on Version: V5.0.10 or above |
Revision | 1 |
Let us know how to improve below document on: support@halny.com |
Upgrade procedure on HUAWEI MA5683T
1. Prepare FTP server and put firmware file on it. Make sure FTP Server is available from OLT
Here is description how archive file should be created.
2. Open diagnose mode
MA5683T(config)#diagnose
3. Define parameters of download FW
MA5683T(diagnose)%%ont-load info program G_ONU_XXX-enc.bin ftp X.X.X.X FTP_USER FTP_PASS
4. Choose ONT which You want to upgrade
MA5683T(diagnose)%%ont-load select FRAME/SLOT PORT-ID ONT-ID
You can choose group of ONTs
MA5683T(diagnose)%%ont-load select FRAME/SLOT PORT-ID ONT-ID_1
MA5683T(diagnose)%%ont-load select FRAME/SLOT PORT-ID ONT-ID_2
...
MA5683T(diagnose)%%ont-load select FRAME/SLOT PORT-ID ONT-ID_n
5. Run upgrade procedure
MA5683T(diagnose)%%ont-load start
6. Check upgrade status
MA5683T(diagnose)%%display ont-load select FRAME/SLOT PORT-ID ONT-ID
--------------------------------------------------------------
F/S/P ONT ID Load state Load progress
--------------------------------------------------------------
0/0/0 16 Loading 80%
--------------------------------------------------------------
MA5683T(diagnose)%%display ont-load select FRAME/SLOT PORT-ID ONT-ID
--------------------------------------------------------------
F/S/P ONT ID Load state Load progress
--------------------------------------------------------------
0/0/0 16 Success 100%
--------------------------------------------------------------
7. Stop upgrade procedure if upgrade completed with success status on all ONTs
MA5683T(diagnose)%%ont-load stop
8. Change active FW, restart ONT
MA5683T(config-if-gpon-0/0)#ont reset PORT-ID ONT-ID